Entry  Mon Aug 1 23:26:32 2011, Koji, Update, LSC, REFL33 PD REFL33_schematic_110801_KA.pdfP8011390.JPG
    Reply  Wed Aug 3 02:20:33 2011, Koji, Update, LSC, REFL165 PD REFL165_schematic_110802_KA.pdfP8031393.JPGP8031391.JPG
       Reply  Wed Aug 3 22:22:47 2011, Koji, Update, LSC, REFL165 PD 
          Reply  Fri Aug 5 04:03:16 2011, Koji, Update, LSC, REFL165 PD P8041394.JPGP8041395.JPGREFL165_test_110804_KA.pdf
    Reply  Wed Aug 3 22:31:38 2011, Koji, Update, LSC, REFL33 PD REFL33_test_110801_KA.pdf
Message ID: 5086     Entry time: Mon Aug 1 23:26:32 2011     Reply to this: 5101   5113
Author: Koji 
Type: Update 
Category: LSC 
Subject: REFL33 PD 

Old MZ PD (InGaAs 2mm, @29.5MHz) has been modified for REFL33.
There has been no choice for the 11MHz notch other than putting it on the RF preamp
as the notch in parellel to the diode eats the RF transimpedance at 33MHz.

I wait for judgement of Rana if the notch at the MAX4107 feedback is acceptable or not.

P8011390.JPG

Attachment 1: REFL33_schematic_110801_KA.pdf  113 kB  | Hide | Hide all
REFL33_schematic_110801_KA.pdf