OSEM damping gains were adjusted by observing real time dataviewer to get Q of 5
OSEMs were kicked up one by one with 200 counts ~1sec. The error signal was optimized to get 1/2 of exitation amplitude at the 5th sinusoid wave.
C1: SUS-ITMX_SUSPOS_N1 gain 111 -> 65, PIT 7.2 -> 8, YAW 12 -> 6, SIDE 280
ITMY 277 -> 120, 19.2 -> 7, 24 -> 19, 420 -> 470
ETMY 10 -> 32, 20 -> 3, 20 -> 10, 50
ETMX 22 -> 25, 3, 3, -170
ETMX having problems: 1, YAW can not be excited
2, SIDE has no error signal in dataviewer. Sensing voltage on MEDM screen 0.142V
|