Subject: WFS1 and 2 gains 

Gains of individual quadrants in both the WFS

As a simple check of the gains on all the quadrants I hooked up the AM (Jenne) laser to put FM modulated light on to the WFS heads and observed the FM modulation frequency , 105 Hz, show up on a power spectrum of the RF outputs.   The plots below show the peak at 105Hz in all the quadrants.

WFS1_7kHz_105Hz.pdf

WFS2_7kHz_105Hz.pdf

 

However I should have put in AM modulation rather FM modulation.  I will do that using the digital system today.  The first version above was done wth a Marconi driving the AM laser modulation.

 

 