40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jul 6 16:44:37 2011, steve, kiwamu, Update, SUS, BS oplev spectra BS.jpg
    Reply  Wed Jul 6 18:15:26 2011, kiwamu, Update, SUS, Re: BS oplev spectra 
    Reply  Tue Jul 12 17:30:24 2011, steve,, Update, SUS, BS oplev spectra BS_oplev.jpg
       Reply  Thu Jul 14 09:38:50 2011, steve,, Update, SUS, BS oplev spectra BS_oplev.jpg
          Reply  Thu Jul 14 15:27:08 2011, steve,, Update, SUS, SUS oplev spectras 7x
             Reply  Fri Jul 15 09:25:02 2011, rana, Update, SUS, SUS oplev spectras 
Message ID: 4972     Entry time: Fri Jul 15 09:25:02 2011     In reply to: 4967
Author: rana 
Type: Update 
Category: SUS 
Subject: SUS oplev spectras 

In addition to the OL quadrants, you need to plot the OPLEV_PERROR and OPLEV_YERROR signals since these are the real signals we use for finding the mirror motion. If they're not in the Dataviewer, Jamie should add them as 256 Hz DAQ channels (using these names so that we have the continuity with the past). These DAQ channels correspond to the IN1 channels for the OL filter banks.

Also JPG are banned from the elog - you should put all of the plots into a single, multipage PDF file in honor of the new Wagonga.

ELOG V3.1.3-