Message ID: 496
Entry time: Sun May 25 19:33:16 2008
|
Author: |
rana |
Type: |
Update |
Category: |
IOO |
Subject: |
MC Bad after Re-alignment |
|
|
The MC pointing was off and the transmitted power was down after John and Andrey brought it back after the bootfest.
I tried getting it back on Friday but was unsuccessful. Today, after the Phoenix Landing, I got it back to someplace
reasonable, but it still seems to be far off. I will check with Rob before we recenter and of the QPDs.
I had to move all of the MC SUS and also align the beam using the IOO periscope. The attached PDF shows some trends
over the last 80 days. You can see that the drop in MC TRANS is about the same as the drop in PMC TRANS. |
|
|