Entry  Sat Jun 25 06:09:38 2011, kiwamu, Update, LSC, Friday locking 
    Reply  Tue Jun 28 15:20:08 2011, kiwamu, Update, LSC, sensing matrix measurement in PRMI configuration rawmatrix.pngsensmat.png
       Reply  Wed Jun 29 12:20:53 2011, kiwamu, Update, LSC, sensing matrix measurement in PRMI configuration 
Message ID: 4910     Entry time: Wed Jun 29 12:20:53 2011     In reply to: 4899
Author: kiwamu 
Type: Update 
Category: LSC 
Subject: sensing matrix measurement in PRMI configuration 

Of course I made a mistake in my calculation of the sensing matrix. I will figure out which point I mistook.

The MICH signal must have the demodulation phase of around 90 deg in AS55

because we had adjusted the demodulation phase such that the MICH signal mostly appears on AS55_Q.

Quote:

Here is the result of the measurement of the sensing matrix in the PRMI configuration.

sensmat.png

ELOG V3.1.3-