Of course I made a mistake in my calculation of the sensing matrix. I will figure out which point I mistook.
The MICH signal must have the demodulation phase of around 90 deg in AS55
because we had adjusted the demodulation phase such that the MICH signal mostly appears on AS55_Q.
Quote: |
Here is the result of the measurement of the sensing matrix in the PRMI configuration.

|
|