40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jun 15 16:37:56 2011, Jenne, Update, PEM, PEM AA Board has been diagnosed and fixed 1X7_AAboard_connector_fix.pdf
    Reply  Thu Jun 16 00:39:08 2011, Koji, Update, PEM, PEM AA Board has been diagnosed and fixed 
Message ID: 4826     Entry time: Thu Jun 16 00:39:08 2011     In reply to: 4825
Author: Koji 
Type: Update 
Category: PEM 
Subject: PEM AA Board has been diagnosed and fixed 

As seen in the photo, the board has a strange bulge on the board,
and
the color of the internal line around the bulge got darkened.

I don't trust this board any more. We should switch to the alternative one.

Quote:

Steve will re-install the board in the rack in the morning.

 

ELOG V3.1.3-