40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri May 6 01:27:12 2011, Koji, Summary, General, aLIGO BBPD / Green PD investigation PD_response.pdfFFD-100_AP389_MCL.pdf
    Reply  Sat May 7 12:57:54 2011, Koji, Summary, General, aLIGO BBPD / Green PD investigation PD_response.pdf
       Reply  Tue May 10 09:05:49 2011, Koji, Update, General, aLIGO BBPD / Green PD investigation PD_response.pdf
          Reply  Wed Jun 1 21:56:43 2011, Koji, Update, General, aLIGO BBPD / Green PD final result PD_response.pdflinearity_GALI_6.pdf
Message ID: 4778     Entry time: Wed Jun 1 21:56:43 2011     In reply to: 4676
Author: Koji 
Type: Update 
Category: General 
Subject: aLIGO BBPD / Green PD final result 

Here is the conclusive result for the circuit configuration for aLIGO BBPD and 40m Green PD.

- Use Mini-circuits MAR-6SM for the RF preamplifier. The 50Ohm input impedance is used for the RF transimpedance.
  The maximum output is ~4dBm.

- Use Mini-circuits GALI-6 for the RF middle power amp. The gain is 12dB and the amplifier is linear up to +17dBm. i.e. This is still linear at the maximum output level of MAR-6SM.

- The total RF transimpedance is ~2k. The DC transimpedance is also 2k.

- The bandwidth is 80MHz with FFD100 and internal 25V bias. When S3399 is used, the bandwdith goes up to 180MHz
although the responsivity of FFD100 at 1064nm is better than S3399 by a factor of 1.5. At the 40m we will use S3399 for the green BB PD.

- By adding an LC network next to the PD, one of the unnecessary signal can be notched out.
As an example, 9MHz notch was placed for the FFD100 case.

- Noise level: ~10pA/rtHz as a floor noise level at around 30MHz. This corresponds to the equivalent dark current of 0.4mA.


Matt has finished the PCB layout. We will order small first batches, and stuff it for the test. Some of these will be the 40m green PD.

Attachment 1: PD_response.pdf  353 kB  Uploaded Wed Jun 1 22:57:59 2011  | Show | Hide all | Show all
Attachment 2: linearity_GALI_6.pdf  24 kB  Uploaded Wed Jun 1 22:58:16 2011  | Hide | Hide all | Show all
linearity_GALI_6.pdf
ELOG V3.1.3-