40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri May 13 23:04:58 2011, Suresh, Update, RF System, DC power supply on RF distribution box has been replaced. P5130120.JPG
    Reply  Sat May 14 14:12:16 2011, Koji, Update, RF System, DC power supply on RF distribution box has been replaced. sorensen.png
       Reply  Wed May 18 15:54:50 2011, Koji, Update, RF System, DC power supplies for the RF generation box in place 
          Reply  Wed May 18 17:06:39 2011, Suresh, Update, RF System, DC power supplies for the RF generation box in place 
    Reply  Sat May 14 14:50:21 2011, Koji, Update, LSC, 1Y2 5V Blown Fuse found -> Fixed 1Y2_5V_Fuse.JPG
Message ID: 4715     Entry time: Fri May 13 23:04:58 2011     Reply to this: 4716   4717
Author: Suresh 
Type: Update 
Category: RF System 
Subject: DC power supply on RF distribution box has been replaced. 

[Steve, Koji, Suresh]

   We shifted two Sorensen power supplies from the Auxiliary rack next to 1X2 to 1Y2.  And have installed them there (pic below).  The local ground reference was picked up from the racks ground reference.  A shielded cable with two twisted pairs was used to make a new power cable for the RF rack.  Since we are using three of the four conductors (+18,+28 and ground), one of them is not connected to anything.  This situation can be improved in a future iteration when, for example, we might wish to relocate the Sorensens to a different rack.

   We are still working on changing the power supply to the RF source.  Will complete this early next week

P5130120.JPG

ELOG V3.1.3-