Message ID: 4681     Entry time: Tue May 10 20:57:05 2011     In reply to: 4672
Author: rana 
Type: Update 
Category: PSL 
Subject: PSL reference cavity temperature box modifications : after 24 hours still OK 

Quote:

I re-installed the box (@ ~8:15) after reflowing some of the solder joints. I will observe it over night and then remove the 1K resistors. Attached is a 8 hour minute-trend.

 I compared this 24 hour trend with the one from this day exactly one year ago. Seems the same, so now I can make the resistor change.