[Valera, Joe]
Software Changes:
First we changed all the C1:IOO-QPD_*_* channels to C1:PSL-QPD_*_* channels in the /cvs/cds/caltech/target/c1iool0/c1ioo.db file, as well as the /opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini file. We then rebooted the frame builder via "telnet fb 8087" and then "shutdown".
This change breaks continuity for these channels prior to today.
The C1:PSL-QPD_POS_HOR and C1:PSL-QPD_POS_VERT channels were found to be backwards as well. So we modified the /cvs/cds/caltech/target/c1iool0/c1ioo.db file to switch them.
Lastly, we changed the ASLO and AOFF values for the C1:PSL-QPD_POS_SUM and the C1:PSL-QPD_ANG_SUM so as to provide positive numbers. This was done by flipping the sign for each entry.
ASLO went from 0.004883 to -0.004883, and AOFF when from -10 to 10 for both channels.
Hardware Changes: