Subject: AS55 demod board with new 90 deg splitter : healthy 

A new 90 deg splitter, PSCQ-2-51W, has been installed on another demod board called AS55.

It shows a reasonably close 90 degree separation between the I and Q signals at 55 MHz with various LO and RF power.

So far we have ordered only three PSCQ-2-51Ws for test. Now we will order some more for the other demodulators.

 Some plots will be posted later.