40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Apr 8 01:05:45 2011, Suresh, Update, RF System, RF Source Harmonics RF_Source_Harmonics_Sheet1.pdf
    Reply  Fri Apr 22 09:05:53 2011, Suresh, Update, RF System, RF Source Harmonics 
       Reply  Fri Apr 22 10:28:22 2011, rana, Update, RF System, RF Source Harmonics 
          Reply  Wed May 4 15:39:32 2011, Suresh, Update, RF System, RF Source Harmonics RF_Harmonics_Sheet1.pdf
Message ID: 4559     Entry time: Fri Apr 22 10:28:22 2011     In reply to: 4557     Reply to this: 4628
Author: rana 
Type: Update 
Category: RF System 
Subject: RF Source Harmonics 
You should be able to resolve the other harmonics by decreasing the IF BW or RBW on the analyzer. Even though
they're OK, its useful to have the final measurement of all of them in some kinds of physical units (like dBm, but
not dBm/Hz or dB or dBcubits).
ELOG V3.1.3-