40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Apr 15 12:17:39 2011, kiwamu, Update, LSC, 11MHz demod board : funny I-Q phase relativephase.png
    Reply  Fri Apr 15 15:15:08 2011, kiwamu, Update, LSC, 11MHz demod board : 90 degree splitter 
       Reply  Sat Apr 16 02:00:14 2011, rana, Update, LSC, 11MHz demod board : 90 degree splitter 
          Reply  Mon Apr 18 13:05:57 2011, kiwamu, Summary, LSC, demod board modification demod_board.png
             Reply  Mon Apr 18 14:11:44 2011, kiwamu, Update, LSC, RF status RF_Work_Status.png
             Reply  Thu Apr 21 21:24:41 2011, kiwamu, Update, LSC, demod board : new 90 deg splitter DSC_2949_ss.jpgDSC_2951.JPGDSC_2952_ss.jpg
                Reply  Thu Apr 21 21:46:22 2011, kiwamu, Update, LSC, demod board : new 90 deg splitter relativephase.png
                   Reply  Fri Apr 22 11:08:50 2011, kiwamu, Update, LSC, demod board AS11 : amplitude imbalance IQamplitude.png
Message ID: 4554     Entry time: Thu Apr 21 21:24:41 2011     In reply to: 4538     Reply to this: 4555
Author: kiwamu 
Type: Update 
Category: LSC 
Subject: demod board : new 90 deg splitter 

A new 90 degree splitter, PSCQ-2-51W, has arrived today and I installed it on a demod board called AS11.

Results of the I-Q phase measurement with the new splitter will be reported soon.

 

 * Picture 1 = before removal of the handmade coil

 * Picture 2 = after removal of the coil and the associated capacitors

 * Picture 3 = after soldering PSCQ-2-51-W

DSC_2949_ss.jpg

DSC_2951.JPG

DSC_2952_ss.jpg

Quote from #4358

 First of all we will replace the home-made 90 degree splitter (see this entry) by a commercial splitter, PSCQ-2-51-W+ from Mini circuit. This is the step 1 basically.