The suggested layout of the 1Y2 Rack is shown below.
To simplify the wiring, I have largely kept demod boards with the same same LO frequency close to each other.
The Heliax cables land on the top and bottom of the of subracks. These are currently flexible plastic sheets. Steve has agreed to replace them with something more rigid. It would be good to have eight N-type connectors on the top and eight at the bottom. As demod boards occur in sets of eight per subrack. So it would be convenient if the 11 and 55 Mhz Heliax cables land on the top and the rest at the bottom. In the layout I have shown the current situation.
The LO signals to the boards come from the RF Distribution box and this is kept in the middle so that cables to both the subracks can be kept short.
The outputs of the AA filter boards from both subracks have to be connected to the SCSI Interface board with a twisted pair ribbon cable.

|