Tue Apr 19 15:48:43 2011, josephb, Update, CDS, MEDM screens and Front Ends updated to new Matrices
|
Tue Apr 19 17:34:02 2011, Koji, Update, CDS, MEDM screens and Front Ends updated to new Matrices
|
Wed Apr 20 11:02:18 2011, josephb, Update, CDS, MEDM screens and Front Ends updated to new Matrices
|
|
Message ID: 4545
Entry time: Wed Apr 20 11:02:18 2011
In reply to: 4544
|
Author: |
josephb |
Type: |
Update |
Category: |
CDS |
Subject: |
MEDM screens and Front Ends updated to new Matrices |
|
|
We simply didn't any matrices larger than 16x16. If we had, than that matrix would not have worked properly since the beginning.
Quote: |
Just a curiosity:
I just wonder how you have distingushed the difference between _111 and _111.
They are equivalent alone themselves. Have you looked at the contexts of the lines?
Or you just did not have the larger matrix than 16x16, did you?
|
|