Entry  Wed Apr 6 19:36:32 2011, Aidan, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies PD_measurement.pngplot_PD_RF_ratios.pdf
    Reply  Thu Apr 7 16:09:17 2011, Aidan, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies 
       Reply  Thu Apr 7 19:28:02 2011, Koji, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies SGD-444A.png
Message ID: 4501     Entry time: Thu Apr 7 19:28:02 2011     In reply to: 4500
Author: Koji 
Type: Summary 
Category: Green Locking 
Subject: (In)sanity check of Green PD - some inconsistencies 

Responsivity of SGD-444A

Quote:

For instance, the PDA100A Si detector from Thorlabs has a responsivity of 0.35-0.4A/W at 1064nm.

 

Attachment 1: SGD-444A.png  59 kB  | Hide | Hide all
SGD-444A.png