40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Mar 30 19:43:33 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
    Reply  Wed Mar 30 19:54:19 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching laser_output_non_circular.png
       Reply  Wed Mar 30 20:08:34 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Beam_Matching_02c_Vertical.pngBeam_Matching_02c_Horizontal.png
          Reply  Wed Mar 30 20:14:17 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
             Reply  Wed Mar 30 20:31:30 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
                Reply  Wed Mar 30 20:50:43 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching After_Faraday.pngAfter_Faraday_and_Rotated_Lens.png
                   Reply  Wed Mar 30 21:21:15 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Oven_Lens_Solution_66mm.pngMatching_Into_Green_Oven_zoomed_out.pngMatching_Into_Green_Oven_zoomed_in.png
                      Reply  Thu Mar 31 02:59:49 2011, Koji, Configuration, Green Locking, The wonderful world of mode-matching 
                         Reply  Thu Mar 31 14:10:00 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching P3310028.JPGP3310029.JPG
                         Reply  Thu Mar 31 15:23:14 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Zoomed_out_fitting01.pngZoomed_in_fitting01.png
                            Reply  Mon Apr 4 14:20:32 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Waist_Fits_from_laser.pngWaist_Fits_Bench_Position.png
Message ID: 4473     Entry time: Thu Mar 31 02:59:49 2011     In reply to: 4470     Reply to this: 4476   4477
Author: Koji 
Type: Configuration 
Category: Green Locking 
Subject: The wonderful world of mode-matching 

 I went through the entries.

1. Give us a photo of the day. i.e. Faraday, tilted lens, etc...

2. After all, where did you put the faraday in the plot of the entry 4466?

3. Zoomed-in plot for the SHG crystal show no astigmatism. However, the zoomed out plot shows some astigmatism.
How consistent are they? ==> Interested in seeing the fit including the zoomed out measurements.