40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Mar 22 00:03:29 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing PSL_vs_Y_arm_Temperatures.png
    Reply  Tue Mar 22 00:23:20 2011, Jenne, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 
       Reply  Tue Mar 22 19:03:45 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 
          Reply  Thu Mar 24 15:30:59 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing Temp_Beating_Day02_html_m2d719182.jpg
             Reply  Thu Mar 24 16:33:32 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing PSL_vs_X-end_T_data_fine.jpg
Message ID: 4423     Entry time: Tue Mar 22 00:23:20 2011     In reply to: 4422     Reply to this: 4425
Author: Jenne 
Type: Configuration 
Category: Green Locking 
Subject: PSL vs Y arm laser temperature pairing 

Quote:

 OK. Today we did the same type of measurement for the Y arm laser as was done for the X arm laser here: http://nodus.ligo.caltech.edu:8080/40m/3759 

And attached here is a preliminary plot of the outcome - oddities with adding on the fitted equations, but they go as follows

(Red)    T_yarm = 1.4435*T_PSL - 14.6222

(Blue)    T_yarm = 1.4223*T_PSL - 10.9818

(Green) T_yarm = 1.3719*T_PSL - 6.3917

 

 It's a bit of a messy plot - should tidy it up later...

 I'm going to take the easy question - What are the pink data points??

ELOG V3.1.3-