Fri Apr 18 16:02:58 2008, alex, Update, SUS, end station sus front-end bug fix
|
Fri Apr 18 16:27:04 2008, rob, Update, SUS, end station sus front-end bug fix
|
Tue Apr 22 16:17:48 2008, rob, Update, SUS, end station sus front-end bug fix
|
|
Message ID: 436
Entry time: Tue Apr 22 16:17:48 2008
In reply to: 425
|
Author: |
rob |
Type: |
Update |
Category: |
SUS |
Subject: |
end station sus front-end bug fix |
|
|
Quote: | installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables. |
What Alex means is that the EPICS values for the ETMY optical levers were being clobbered in the RFM. The calculations were being done correctly in the FE, so the DAQ/testpoints were working--it was just the EPICS/RFM communication via c1losepics that was bugged. This was a result of the recent SUS code changes to accept inputs from the ASS for adaptive feedforward. |