Message ID: 4212     Entry time: Thu Jan 27 15:16:43 2011
Author: josephb 
Type: Update 
Category: CDS 
Subject: Updated generate_master_screens.py 

I modified the generate_master_screens.py script in /opt/rtcds/caltech/c1/medm/master/ to handle changing the MCL (and MC_L) listings to ALS for the two ETM suspension screens and associated sub-screens.

The relevant added code is:

custom_optic_channels = ['ETMX',
{'MCL':'ALS','MC_L':'ALS'},
'ETMY',
{'MCL':'ALS','MC_L':'ALS'}]

 

for index in range(len(custom_optic_channels)/2):
   if optic == custom_optic_channels[index*2]:
     for swap in custom_optic_channels[index*2+1]:
       sed_command = start_sed_string + swap + "/" + custom_optic_channels[index*2+1][swap] + middle_sed_string + optic + file
       os.system(sed_command)

When run, it generates the correctly named C1:SUS-ETMX_ALS channels, and replaces MCL and MC_L with ALS in the matrix screens.

 