Entry  Tue Jan 25 22:49:13 2011, Koji, Update, CDS, Front End multiple crash 
    Reply  Wed Jan 26 10:58:48 2011, josephb, Update, CDS, Front End multiple crash 
       Reply  Wed Jan 26 12:03:45 2011, Koji, Update, CDS, Front End multiple crash 
Message ID: 4207     Entry time: Wed Jan 26 12:03:45 2011     In reply to: 4206
Author: Koji 
Type: Update 
Category: CDS 
Subject: Front End multiple crash 

This is definitely a nice magic to know as the rebooting causes too much hustles.

Also, you and I should spend an hour in the afternoon to add the suspension swtches to the burt requests.

Quote:

I killed the dead c1lsc model by typing:

sudo rmmod c1lscfe

I then tried starting just the front end model again by going to the /opt/rtcds/caltech/c1/target/c1lsc/bin/ directory and typing:

sudo insmod c1lscfe.ko

This started up just the FE again

 