Message ID: 4149     Entry time: Thu Jan 13 12:56:57 2011     In reply to: 4148
Author: rana 
Type: Update 
Category: IOO 
Subject: WFS shenanigans 

Actually, I just found out that there are different flavors of 'YAG-444'.

There's a YAG-444AH and also a YAG-444-4AH. I'm not sure which one we have or even which is better. The diode's internal resistance is not listed.

They also say explicitly that he 'YAG Enhancement' is just using thicker Silicon. Since the absorption of 1064 nm light in Silicon is very small, most of the light just goes in and then comes back out without depositing much of the power.

Attachment 1: PerkinElmerQPDs.pdf  208 kB  | Hide | Hide all
PerkinElmerQPDs.pdf PerkinElmerQPDs.pdf