Entry  Wed Jan 5 00:23:30 2011, rana, Summary, DAQ, FrameBuilder fails in a new way 
    Reply  Wed Jan 5 16:00:11 2011, rana, alex, Summary, DAQ, FrameBuilder fails in a new way 
       Reply  Wed Jan 5 22:14:41 2011, rana, Summary, DAQ, FrameBuilder fails in a new way Screen_shot_2011-01-05_at_10.13.21_PM.png
Message ID: 4109     Entry time: Wed Jan 5 00:23:30 2011     Reply to this: 4112
Author: rana 
Type: Summary 
Category: DAQ 
Subject: FrameBuilder fails in a new way 

Since Leo was trying to demo his LIGO Data Listener code, he noticed that there was and NDS2 issue. The NDS2 guy (JZ) noticed that the FrameBuilder had an issue.

We investigated. At 4PM on Dec 31, the GPS timestamp of the frame file names started to be recorded wrong. In fact, it started to give it a file name matching the correct time from 1 year in the past.

So that's our version of the Y2011 bug. Here's the 'ls' of /frames/full:

drwxr-xr-x 2 controls controls 252K Dec 26 03:59 9773
drwxr-xr-x 2 controls controls 260K Dec 27 07:46 9774
drwxr-xr-x 2 controls controls 256K Dec 28 11:33 9775
drwxr-xr-x 2 controls controls 252K Dec 29 15:19 9776
drwxr-xr-x 2 controls controls 244K Dec 30 19:06 9777
drwxr-xr-x 2 controls controls 188K Dec 31 16:00 9778
drwxr-xr-x 2 controls controls 148K Jan  1 08:53 9463
drwxr-xr-x 2 controls controls 260K Jan  2 12:39 9464
drwxr-xr-x 2 controls controls 252K Jan  3 16:26 9465
drwxr-xr-x 2 controls controls 248K Jan  4 20:13 9466
drwxr-xr-x 2 controls controls  36K Jan  5 00:22 9467
controls@fb /frames/full $

The culprit is the directory who's name starts out as 9463 whereas it should be 9779.

 