40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Dec 8 14:51:09 2010, josephb, Update, CDS, c1pem now recording data 
    Reply  Sat Jan 1 19:13:40 2011, rana, Update, CDS, c1pem now recording data Untitled.png
Message ID: 4101     Entry time: Sat Jan 1 19:13:40 2011     In reply to: 4028
Author: rana 
Type: Update 
Category: CDS 
Subject: c1pem now recording data 

 I found that there was no PEM data nor any other data (no SUS or otherwise. No testpoints, no DAQ).

I went through the procedure that Jenne has detailed in the Wiki but it didn't work.

1) Firstly, the 'telnet fb 8088' step doesn't work. It says "Connected to fb.martian" but then just hangs. To replicate the effect of this step I tried ssh'ing to fb and doing a 'pkill daqd'. That works to restart the daqd process.

2) The wiki instructions had a problem. In the GUI step, it should say 'Save' after the Acquire bit has been set to 1. Even so, this works to get the .ini file right and the DTT can see the correct channel list, but none of the channels are available. There are just 'Unable to obtain measurement data'.

3) I tried running 'startc1pem', but no luck. I also tried rebooting c1sus from the command line. That worked so far as to come back up with all the right processes running, but still no data. The actual /frames directory shows that there are frames, but we just can't see the data. I also tried to get data usind the DTT-NDS2 method, but still no luck. (*** ITMX and ITMY both came back with all their filters off; worth checking if their BURTs are working correctly.)

Using DataViewer, however, I AM able to see the data (although the channel name is RED). In fact, I am able to see the trend data ever since I changed the Acquire bit to 1. Plot attached as evidence. Why does DTT not work anymore???

Attachment 1: Untitled.png  6 kB  | Hide | Hide all
Untitled.png
ELOG V3.1.3-