Fri Nov 5 15:20:18 2010, josephb, alex, Summary, CDS, 40m computer slow down solved
|
Fri Nov 5 21:49:12 2010, rana, Summary, CDS, 40m computer slow down solved
|
Sat Nov 6 16:13:14 2010, rana, Summary, CDS, 40m computer slow down solved
|
|
Message ID: 3872
Entry time: Fri Nov 5 21:49:12 2010
In reply to: 3869
Reply to this: 3877
|
Author: |
rana |
Type: |
Summary |
Category: |
CDS |
Subject: |
40m computer slow down solved |
|
|
Quote: |
Problem:
The 40m computers were responding sluggishly yesterday, to the point of being unusable.
Cause:
The mx_stream code running on c1iscex (the X end suspension control computer) went crazy for some reason. It was constantly writing to a log file in /cvs/cds/rtcds/caltech/c1/target/fb/192.168.113.80.log. In the past 24 hours this file had grown to approximatel
|
The moral of the story is, PUT THINGS IN THE ELOG. This wild process is one of those things where people say 'this won't effect anything', but in fact it wastes several hours of time. |