Entry  Mon Nov 1 19:32:08 2010, yuta, Summary, CDS, fb crashed? during c1ioo and c1mcs connection at ASC 
    Reply  Wed Nov 3 21:19:40 2010, yuta, Update, CDS, put LOCKIN to c1ioo model and checked Screenshot_C1IOO_LOCKIN.png
Message ID: 3841     Entry time: Mon Nov 1 19:32:08 2010     Reply to this: 3857
Author: yuta 
Type: Summary 
Category: CDS 
Subject: fb crashed? during c1ioo and c1mcs connection at ASC 

Frame builder died again!!

Background:
  We want to do angle to length measurement to optimize the beam position and increase visibility of MC locking.
  In order to do A2L measurement, we need excitation point, but AWG is currently not working.
  The better way is to use LOCKIN stuff like we had for OMC and put it to C1IOO WFS.
  A software oscillator in LOCKIN shakes the suspension, and demodulate the length signal.
  We can choose whatever DOF to shake, whatever signal to demodulate. It would be useful not just for A2L.

What I did:

  I started to put C1IOO WFS signal into C1SUS MC suspension RT model, but after compiling new c1mcs, fb crashed.
  Looks like daqd and mx_streams are running, but DAQ is not working(red).
  I don't know how to restart in a new way!