Problem:
Need a working IO chassis connected to c1ioo in order to bring the MC_L into the digital realm, and then via RFM transmit to the c1sus machine.
Attempted Solution:
Move the c1iscey IO chassis to c1ioo while the c1ioo chassis is at downs.
The c1iscey chassis however doesn't seem to be talking to the c1ioo computer. I tried changing the host interface card on the c1ioo chassis. I took out One Stop Systems HIB2-x4-H interface card with serial number 26638 from the c1ioo computer and put in the One Stop Systems HIB2-x4-H with serial number 35242 in from c1iscey into c1ioo. Still didn't work.
All the lights are red on the interface card on the actual chassis and its cooling fan isn't spinning.
Using dmesg on c1ioo shows that it does not see any of the ADC/DAC/BO cards.
Status:
I'm going to wait until tomorrow morning when Rolf gets a chance to look at the c1ioo chassis over at Downs to determine the next step. If we fix the c1ioo chassis, I'm move the c1iscey chassis and its host interface board back to the end. |