Entry  Mon Aug 30 23:21:36 2010, rana, HowTo, PSL, 2W NPRO Mount designed with emachineshop.com software LaserMount.png
    Reply  Tue Aug 31 19:46:00 2010, rana, Update, PSL, PSL upgrade update 
       Reply  Wed Sep 1 08:28:43 2010, Koji, Update, PSL, PSL upgrade update 
    Reply  Wed Sep 1 08:36:59 2010, Koji, HowTo, PSL, 2W NPRO Mount designed with emachineshop.com software 
Message ID: 3503     Entry time: Wed Sep 1 08:36:59 2010     In reply to: 3491
Author: Koji 
Type: HowTo 
Category: PSL 
Subject: 2W NPRO Mount designed with emachineshop.com software 

1. I can not see whether the attaching surface is flat or not.
It should have ~1mm step to avoid "the legs" of the laser at the four corners.
Otherwise we will have ~0.5mm space between the block and the laser
and will squish this gap by the screws => cause the deformation of the block and the laser.

2. The countersinks for the M4 screws can be much deeper so that we can use the existing M4 screws.
In any case, the long M4 screws are not rigid and also not common.

Quote:

To test out this website - emachineshop.com, Jenne and I are designing some of the mounts for the new beam height.

LaserMount.png

It took me a few hours to figure out how to do it, but the software is easy enough for simple stuff. This is a brass mount with M4 clearance holes which are countersunk and a lip so that it can be dogged down to the table.

 