40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Aug 4 16:52:59 2010, Razib, Aidan, Update, Phase Camera, Sideband power measurement (updated)  
|
Thu Aug 12 16:52:02 2010, Razib, Update, Phase Camera, Sideband power measurement (updated)    
|
Thu Aug 12 17:10:07 2010, Koji, Update, Phase Camera, Sideband power measurement (updated)
|
Thu Aug 12 17:28:28 2010, Razib, Update, Phase Camera, Sideband power measurement (updated)
|
|
Message ID: 3413
Entry time: Thu Aug 12 17:28:28 2010
In reply to: 3412
|
Author: |
Razib |
Type: |
Update |
Category: |
Phase Camera |
Subject: |
Sideband power measurement (updated) |
|
|
Quote: |
This sounds very relieving although this could be a lower bound of the number.
Why didn't you use the output on the PD which just give us the direct observation of your so-called SCR.
Quote: |
So the SCR is calculated by the ratio of the FFT'd DC and the 5 Hz signal. Using the CCD, I obtained the SCR to be 0.075 ± 0.01. Previously, we expected our SCR to be 0.09 as in the previous e-log entry.
|
|
The SCR was at first measured using the output of the PD. That was exactly from where we got our 0.09 (previous elog entry). The second measurement was from the CCD. |