Wed Aug 4 16:52:59 2010, Razib, Aidan, Update, Phase Camera, Sideband power measurement (updated)  
|
Thu Aug 12 16:52:02 2010, Razib, Update, Phase Camera, Sideband power measurement (updated)    
|
Thu Aug 12 17:10:07 2010, Koji, Update, Phase Camera, Sideband power measurement (updated)
|
Thu Aug 12 17:28:28 2010, Razib, Update, Phase Camera, Sideband power measurement (updated)
|
|
Message ID: 3412
Entry time: Thu Aug 12 17:10:07 2010
In reply to: 3411
Reply to this: 3413
|
Author: |
Koji |
Type: |
Update |
Category: |
Phase Camera |
Subject: |
Sideband power measurement (updated) |
|
|
This sounds very relieving although this could be a lower bound of the number.
Why didn't you use the output on the PD which just give us the direct observation of your so-called SCR.
Ed: I meant time series of the PD output
Quote: |
So the SCR is calculated by the ratio of the FFT'd DC and the 5 Hz signal. Using the CCD, I obtained the SCR to be 0.075 ± 0.01. Previously, we expected our SCR to be 0.09 as in the previous e-log entry.
|
|