40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 2983     Entry time: Tue May 25 16:40:27 2010
Author: josephb, alex 
Type: Update 
Category: CDS 
Subject: Finally tracked down why new models wouldn't talk to each other 

The problem with the new models using the new shared memory/dolphin/RFM defined as names in a single .ipc file.

The first is the no_oversampling flag should not be used.  Since we have a single IO processor handling ADCs and DACs at 64k, while the models run at 16k, there is some oversampling occuring.  This was causing problems syncing between the models and the IOP.

It also didn't help I had a typo in two channels which I happened to use as a test case to confirm they were talking.  However, that has been fixed.