Author: Alberto 
Type: Update 
Category: 40m Upgrading 
Subject: New improved design for the 11MHz photodiode 

After munching analytical models, simulations, measurements of photodiodes I think I got a better grasp of what we want from them, and how to get it. For instance I now know that we need a transimpedance of about 5000 V/A if we want them to be shot noise limited for ~mW of light power.

Adding 2-omega and f1/f2 notch filters complicates the issue, forcing to make trade-offs in the choice of the components (i.e., the Q of the notches)

Here's a better improved design of the 11Mhz PD.

Attachment 1: pox11.pdf  13 kB  | Hide | Hide all
pox11.pdf