Entry  Sun May 2 13:04:51 2010, Koji, Summary, SUS, Coil Actuator Balancing and Spot Position coil_balance.png
    Reply  Sun May 2 15:38:12 2010, rana, Summary, SUS, Coil Actuator Balancing and Spot Position 
       Reply  Sun May 2 16:52:44 2010, Koji, Summary, SUS, Coil Actuator Balancing and Spot Position 
Message ID: 2865     Entry time: Sun May 2 15:38:12 2010     In reply to: 2863     Reply to this: 2866
Author: rana 
Type: Summary 
Category: SUS 
Subject: Coil Actuator Balancing and Spot Position 

 

Oh, but it gets even better: in order to trust the A2L script in this regard you have to know that the coil driver - coil - magnet gain is the same for each channel. Which you can't.

But we have these handy f2pRatio scripts that Vuk and Dan Busby worked on. They use the optical levers to balance the actuators at high frequency so that the A2L gives you a true spot readout.

But wait! We have 4 coils and the optical lever only gives us 2 signal readouts...