Sat Apr 24 15:05:41 2010, Kevin, Update, PSL, 2W Vertical Beam Profile
|
Sat Apr 24 15:50:47 2010, Koji, Update, PSL, re: 2W Vertical Beam Profile
|
Mon Apr 26 16:51:37 2010, Kevin, Update, PSL, re: 2W Vertical Beam Profile
|
Mon Apr 26 17:34:31 2010, Koji, Update, PSL, re: 2W Vertical Beam Profile
|
Tue Apr 27 15:29:16 2010, Kevin, Update, PSL, re: 2W Vertical Beam Profile 
|
Wed Apr 28 14:22:36 2010, Kevin, Update, PSL, re: 2W Vertical Beam Profile
|
|
Message ID: 2857
Entry time: Wed Apr 28 14:22:36 2010
In reply to: 2851
|
Author: |
Kevin |
Type: |
Update |
Category: |
PSL |
Subject: |
re: 2W Vertical Beam Profile |
|
|
I used the Mathematica CurveFit package that we use in Ph6/7 to make the fits for the beam profile data. I wrote two functions that use CurveFit shown in the attachment to make the fits to the error function and square root. |
|