Entry  Tue Apr 20 20:15:37 2010, Kevin, Update, PSL, Innolight 2W Output Power vs Injection Current PvsI_2W.jpg
    Reply  Wed Mar 28 17:28:58 2018, Steve, Update, PSL, noise eater on or off inno2W.pnginno1W.png
Message ID: 2822     Entry time: Tue Apr 20 20:15:37 2010     Reply to this: 13714
Author: Kevin 
Type: Update 
Category: PSL 
Subject: Innolight 2W Output Power vs Injection Current 

Koji and Kevin measured the output power vs injection current for the Innolight 2W laser.

The threshold current is 0.75 A.

 

The following data was taken with the laser crystal temperature at 25.04ºC (dial setting: 0.12).

Injection Current (A) Dial Setting Output Power (mW)
0.000 0.0 1.2
0.744 3.66 1.1
0.753 3.72 4.6
0.851 4.22 102
0.954 4.74 219
1.051 5.22 355
1.151 5.71 512
1.249 6.18 692
1.350 6.64 901
1.451 7.08 1118
1.556 7.52 1352
1.654 7.92 1546
1.761 8.32 1720
1.853 8.67 1855
1.959 9.05 1989
2.098 9.50 2146

 

Attachment 1: PvsI_2W.jpg  15 kB  | Hide | Hide all
PvsI_2W.jpg