40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jan 28 18:56:47 2008, rana, Update, DMF, seisBLRMS 1.0 
    Reply  Tue Jan 29 14:56:39 2008, rob, Update, DMF, seisBLRMS 1.0 
Message ID: 282     Entry time: Mon Jan 28 18:56:47 2008     Reply to this: 284
Author: rana 
Type: Update 
Category: DMF 
Subject: seisBLRMS 1.0 
I made all of the updates I aludded to before:

  • Expanded the dmf.db file on c1aux to include all accelerometers and the seismometer.
  • Added the channels to the C0EDCU.ini file and restarted the framebuilder daqd.
  • Modified seisBLRMS.m to use .conf files for the channels. The .conf files are now residing in the compiled matlab directory that Rob made.

I still have yet to compile and test the new version. Its running on linux3 right now, but feel free to kill it and compile it to run on Mafalda.

It should be making trends overnight and so we can finally see what the undergrads are really up to.