40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Apr 1 00:43:33 2010, Mott, Update, General, PZT response for the innolight Innolight_Bode.png
    Reply  Thu Apr 1 07:17:15 2010, Koji, Update, General, PZT response for the innolight 
       Reply  Thu Apr 1 10:21:58 2010, Mott, Update, General, PZT response for the innolight Innolight_Response.pngLightwave_response.png
          Reply  Thu Apr 1 10:47:48 2010, Koji, Update, General, PZT response for the innolight 
             Reply  Thu Apr 1 12:07:22 2010, rana, Update, General, PZT response for the innolight 
                Reply  Thu Apr 1 18:05:29 2010, Mott, Update, General, PZT response for the innolight Innolight_Response_calFix.pngLightwave_response_calFix.png
                   Reply  Thu Apr 1 18:44:40 2010, Koji, Update, General, PZT response for the innolight 
                      Reply  Thu Apr 1 19:59:32 2010, Mott, Update, General, PZT response for the innolight Innolight_AM_Response.pngInnolight_AM_PM.pngInnoVsLW_PM.pngInnolight_AM_Response.pngLightwave_AM_PM.png
                         Reply  Mon Apr 12 14:20:10 2010, kiwamu, Update, Green Locking, PZT response for the innolight 
                            Reply  Tue Apr 13 19:53:06 2010, Mott, Update, Green Locking, PZT response for the innolight and lightwave 6x
Message ID: 2788     Entry time: Mon Apr 12 14:20:10 2010     In reply to: 2756     Reply to this: 2799
Author: kiwamu 
Type: Update 
Category: Green Locking 
Subject: PZT response for the innolight 

I measured a jitter modulation caused by injection of a signal into laser PZTs.

The measurement has been done by putting a razor blade in the middle way of the beam path to cut the half of the beam spot, so that a change of intensity at a photodetector represents the spatial jitter of the beam.

However the transfer function looked almost the same as that of amplitude modulation which had been taken by Mott (see the entry).

This means the data is dominated by the amplitude modulation instead of the jitter. So I gave up evaluating the data of the jitter measurement.

ELOG V3.1.3-