Message ID: 256     Entry time: Wed Jan 23 12:31:36 2008
Author: Andrey 
Type: Summary 
Category: SUS 
Subject: Dissapointing Results of XARM optimization (PDF-file) 

I attach a PDF-file which summarizes briefly the results of measurements/calculations of Q-factors for ITMX mass as a function of suspension damping gain,

and this file contains the results of measurements of RMS peaks on the values of suspension gains of ITMX and ETMX (see ELOG entries from December 2007, specifically #202, #199, #194)),
but now those dependences are plotted in Q-ITMX and Q_ETMX axes.

Unfortunately, there are no clear narrow areas of minimum in those dependences (that explains the sad title of this ELOG entry).

The attached pdf-file can be shown as a short presentation for a wall during our Wednesday meeting.
Attachment 1: Sad_Results_XARM.pdf  370 kB  | Show | Show all