This is perhaps best put in the LLO elog, but I'm not yet a 'person' there, so I can't write to their elog (yet another thing for the eternal to-do list). So for now, we're putting things here...
This isn't totally finalized, but I do want to get what I have posted before I hop on a plane in the morning. Mostly it just needs more time to run, to make the plot longer. Hopefully I'll be able to edit this in the morning and have a longer-duration plot.
What's plotted:
This spectrogram shows the amplitude spectra of L1:LSC-DARM_CTRL, after being subtracted via a Static Wiener Filter. Each spectra is normalized by the very first one, which was created from the same data that was used to determine the Wiener Filter. The X-axis is time. The Y-axis is frequency, and the Color/Z-axis is amplitude in dB. I'm only looking at Science Mode time, so other times when the IFO isn't in science mode, I plot a black stripe to fill in the plot. The start time of the plot is 83675598, which is Jul 08 2006 06:33:04 UTC.
Why?
The idea is to see that the filter does equally well a long time after it was created, as when it was initially made. This will help tell us how often it is useful to recompute the Wiener filters. Less often is nice, because redoing the Wiener filters may also include remeasuring the high precision transfer functions...if the filter isn't working as well anymore it may be because the transfer function has changed ever so slightly.
How the plot is created / the background story:
I use one hour of DARM_CTRL data and the following seismometer channels to create an optimal Wiener Filter (pem indicates L0:PEM- , sei indicates L1:SEI- , and lsc indicates L1:LSC- ) :
chans = {[pem 'EX_SEISX'],...
[pem 'EX_SEISY'],...
[pem 'EX_SEISZ'],...
[pem 'EY_SEISX'],...
[pem 'EY_SEISY'],...
[pem 'EY_SEISZ'],...
[pem 'LVEA_SEISX'],...
[pem 'LVEA_SEISY'],...
[pem 'LVEA_SEISZ'],...
[sei 'LVEA_STS2_X'],...
[sei 'LVEA_STS2_Y'],...
[sei 'LVEA_STS2_Z'],...
[sei 'ETMX_STS2_X'],...
[sei 'ETMX_STS2_Y'],...
[sei 'ETMX_STS2_Z'],...
[sei 'ETMY_STS2_X'],...
[sei 'ETMY_STS2_Y'],...
[sei 'ETMY_STS2_Z'],...
[lsc 'DARM_CTRL']};
I then apply this one filter to ten minute chunks of science mode data, for some long period of time. The game plan is to have a month long plot, but it takes a while to fetch all of the data in separate 10min intervals (~45sec per iteration, times ~3000 iterations), so this plot isn't a full month. Even if I don't get a chance to plot a full month by Thursday morning, it'll go up here within the next few days. The particular times chosen have the most science mode data within a 30 day period. I can easily run the code for some other time, if there is a known time (or season) which might be more interesting. For the spectrogram plot, I then normalize each amplitude spectra by the first one, which comes from the first ten minutes in the hour which was used to make the filter. This makes it easier to see how the filter's efficacy changes over time.
The analogous analysis for Hanford is in the 40m elog: 1606. The Hanford stuff in the elog has some cool BLRMS plots also, but I'm not sure that they're so helpful when I only have a few days of L1 data so far. I'll do those and add them later.
Conclusions:
I can't really say anything yet about the long-term efficacy of a Wiener Filter for LLO yet, since my code hasn't finished filtering my one month of S5 L1 data. It definitely looks like (so far) that there was a big seismic event around the (arbitrarily defined) 'Day 4'. |