40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Nov 25 20:24:49 2009, Alberto, Update, ABSL, PLL Open Loop Gain Measured 2009-09-25_OLgain_g3png.png2009-09-25_OLgain_g6png.png
    Reply  Fri Nov 27 02:25:26 2009, rana, Update, ABSL, PLL Open Loop Gain Measured 
Message ID: 2338     Entry time: Wed Nov 25 20:24:49 2009     Reply to this: 2342
Author: Alberto 
Type: Update 
Category: ABSL 
Subject: PLL Open Loop Gain Measured 

I measured the open loop gain of the PLL in the AbsL experiment.

I repeated the measurement twice: one with gain knob on the universal PDH box g=3.0; the second measurement with g=6.0

The UGF were 60 KHz and 100 KHz, respectively.

That means that one turn of the knob equals to about +10 dB.

Attachment 1: 2009-09-25_OLgain_g3png.png  57 kB  | Hide | Hide all
2009-09-25_OLgain_g3png.png
Attachment 2: 2009-09-25_OLgain_g6png.png  59 kB  | Hide | Hide all
2009-09-25_OLgain_g6png.png