I have been working about multi-resonant EOM since last week.
In order to characterize the behavior of the each components, I have made a simple LC tank circuit.
You can see the picture of the circuit below.

Before constructing the circuit, I made an "ideal" calculation of the transfer function without any assumptions by my hand and pen.
Most difficult part in the calculation is the dealing with a transformer analytically. Eventually I found how to deal with it in the analytical calculation.
The comparison of the calculated and measured transfer function is attached.
It shows the resonant frequency of ~50MHz as I expected. Those are nicely matched below 50MHz !!
For the next step, I will make the model of the circuit with stray capacitors, lead inductors, ... by changing the inductance or something.
|