[Sanjit,Jenne]

Sanjit has been working today on trying to get the OAF coefficients to save properly.  Alex got us most of the way, but right now it's looking like the filter that is being saved is totally constant (all the values are the same).  We're poking around trying to figure out why this is. 

Also, we're starting again (as we should have been for the last week or so since Alex came in to help us) to check in the TOP_XFCODE whenever we make changes to it, and when we recompile the front end code. 

 

We are manually restarting assepics, but the terminal logs us out after sometime and ass may crash. I set autologout=0 in the terminal for the time being. Once the testing process is over, assepics will start automatically when the computer is turned on, so we wont have to worry about this.

(if ass crashes tonight, it is not unexpected!)

 