40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Oct 7 20:32:21 2009, rana, Update, Adaptive Filtering, extra delay and noise in PEM -> ASS/OAF system a.gif
    Reply  Mon Oct 19 11:31:55 2009, Jenne, Update, Adaptive Filtering, extra delay and noise in PEM -> ASS/OAF system PEM-timing_19Oct2009.png
       Reply  Mon Oct 19 19:37:39 2009, Sanjit, Jenne, Update, Adaptive Filtering, extra delay and noise in PEM -> ASS/OAF system PEM_timingDealy_19OCT09_MCL2PEM2.png
          Reply  Tue Oct 20 11:38:10 2009, rana, rolf, Update, Adaptive Filtering, extra delay and noise in PEM -> ASS/OAF system 
Message ID: 2125     Entry time: Tue Oct 20 11:38:10 2009     In reply to: 2121
Author: rana, rolf 
Type: Update 
Category: Adaptive Filtering 
Subject: extra delay and noise in PEM -> ASS/OAF system 

An email from Rolf about the delay in the 110Bs:

"...we do take the ~2msec pipeline delay into account when we send the data to DAQ. If I remember correctly, the delay is about 39 samples. On startup, the first 39 samples are 'thrown away', such that, from then on, data lines up with the correct time (just read 2msec later then Penteks)."

ELOG V3.1.3-