Message ID: 2050     Entry time: Mon Oct 5 10:41:31 2009     In reply to: 2049     Reply to this: 2055
Author: Koji 
Type: Update 
Category: PSL 
Subject: PSL laser accidentally turned off 

The PSL output looks smaller than the incident. Try to FSS Slow actuator adj of -5.6 (nominal), instead of -3.5.

Quote:

Alberto, Steve,

While I was moving a cart near by the PSL table I pushed the red emergency button that turns off the PSL laser. We had to unlock the button and then power cycle the laser driver to turn the laser back on.

I relocked MZ, FSS, PMC and I'm now waiting for the power to finish ramping up back to the previous value.

 