Message ID: 205     Entry time: Thu Dec 20 02:04:09 2007
Author: Andrey 
Type: Update 
Category: Computer Scripts / Programs 
Subject: New overnight measurements in XARM and their results 

I ran in the daytime/evening time my program, changing the damping gains in suspension "position" degree of freedom for ETMX and ITMX
in the interval from 1.00 to 3.75 with the step 0.25 (see entry # 201).

Now I am running overnight (from 2AM till 9AM) the program changing the gains in the interval from 1.3 to 3.5 with the step 0.20,
12 X 12 = 144 experimental points. I started so late because I fell asleep after my Wednesday evening dinner, then woke up half an hour ago and hurried to the lab.

BELOW: RESULTS OF MEASUREMENTS WERE ADDED ON THURSDAY EVENING, DEC. 20.

All the meaning of the attachments 1-3, 4-6, 7-9, 10-11 is the same as in previous ELOG entries # 195, # 199, # 202, see in those entries which graph corresponds to which coordinate axes orientation.
Attachment 1: RMS-08Hz-Top-View.png  13 kB  Uploaded Thu Dec 20 21:13:44 2007  | Hide | Hide all
RMS-08Hz-Top-View.png
Attachment 2: RMS-3Hz-Top-View.png  18 kB  Uploaded Thu Dec 20 21:13:55 2007  | Hide | Hide all
RMS-3Hz-Top-View.png
Attachment 3: RMS-broadband-Top-View.png  14 kB  Uploaded Thu Dec 20 21:14:05 2007  | Hide | Hide all
RMS-broadband-Top-View.png
Attachment 4: RMS-08Hz-Side_View.png  12 kB  Uploaded Thu Dec 20 21:14:15 2007  | Hide | Hide all
RMS-08Hz-Side_View.png
Attachment 5: RMS-3Hz-Side_View.png  17 kB  Uploaded Thu Dec 20 21:14:25 2007  | Hide | Hide all
RMS-3Hz-Side_View.png
Attachment 6: RMS-broadband-Side_View.png  13 kB  Uploaded Thu Dec 20 21:14:34 2007  | Hide | Hide all
RMS-broadband-Side_View.png
Attachment 7: RMS-08Hz-Q_I-Q_E-Axes.png  13 kB  Uploaded Thu Dec 20 21:14:45 2007  | Hide | Hide all
RMS-08Hz-Q_I-Q_E-Axes.png
Attachment 8: RMS-3Hz-Q_I-Q_E-Axes.png  18 kB  Uploaded Thu Dec 20 21:14:55 2007  | Hide | Hide all
RMS-3Hz-Q_I-Q_E-Axes.png
Attachment 9: RMS-broadband-Q_I-Q_E-Axes.png  12 kB  Uploaded Thu Dec 20 21:15:03 2007  | Hide | Hide all
RMS-broadband-Q_I-Q_E-Axes.png
Attachment 10: Accelerometer-ETMX.png  16 kB  Uploaded Thu Dec 20 21:54:37 2007  | Hide | Hide all
Accelerometer-ETMX.png
Attachment 11: Accelerometer-ITMX.png  15 kB  Uploaded Thu Dec 20 21:54:46 2007  | Hide | Hide all
Accelerometer-ITMX.png
ELOG V3.1.3-