Author: rana 
Type: Update 
Category: Computers 
Subject: c1susvme2 timing problems update 

The attached shows the 200 day '10-minute' trend of the CPU meters and also the room temperature.

To my eye there is no correlation between the signals. Its clear that c1susvme2 (SRM LOAD) is going up and no evidence that its temperature.

 

Attachment 1: Untitled.png  61 kB  | Hide | Hide all
Untitled.png