Entry  Fri Aug 7 16:00:17 2009, pete, Update, Computers, RCG work. MDC MDP open loop transfer function tf_au_natural.pdf
    Reply  Sun Aug 9 16:32:18 2009, rana, Update, Computers, RCG work. MDC MDP open loop transfer function a.png
Message ID: 1856     Entry time: Fri Aug 7 16:00:17 2009     Reply to this: 1870
Author: pete 
Type: Update 
Category: Computers 
Subject: RCG work. MDC MDP open loop transfer function 

Today I was able to make low frequency transfer function with DTT on megatron.  There seems to have been a timing problem, perhaps Alex fixed it or it is intermittent.

I have attached the open loop transfer function for the un-optimized system, which is at least stable to step impulses with the current filters and gains.  The next step is to optimize, transfer this knowledge to the ADC/DAC version, and hook it up to isolated ETMX.

Attachment 1: tf_au_natural.pdf  5 kB  Uploaded Fri Aug 7 17:03:55 2009  | Hide | Hide all
tf_au_natural.pdf tf_au_natural.pdf