sudo fsck -yV UUID="90a5c98a-22fb-4685-9c17-77ed07a5e000" [238/276] [sudo] password for controls: fsck from util-linux 2.20.1 [/sbin/fsck.ext4 (1) -- /media/40mBackup] fsck.ext4 -y /dev/sde1 e2fsck 1.42 (29-Nov-2011) /dev/sde1 contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Error reading block 527433852 (Attempt to read block from filesystem resulted in short read) while getting next inode from scan. Ignore error? yes Force rewrite? yes Pass 2: Checking directory structure Error reading block 519578253 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes Force rewrite? yes Directory inode 129893610, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 129893610. Fix? yes Setting filetype for entry '.' in ??? (129893610) to 2. Missing '..' in directory inode 129893610. Fix? yes Setting filetype for entry '..' in ??? (129893610) to 2. Error reading block 521150498 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes Force rewrite? yes Directory inode 130285571, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 130285571. Fix? yes Setting filetype for entry '.' in ??? (130285571) to 2. Missing '..' in directory inode 130285571. Fix? yes Setting filetype for entry '..' in ??? (130285571) to 2. Error reading block 521150499 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes [191/276] Force rewrite? yes Directory inode 130285572, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 130285572. Fix? yes Setting filetype for entry '.' in ??? (130285572) to 2. Missing '..' in directory inode 130285572. Fix? yes Setting filetype for entry '..' in ??? (130285572) to 2. Error reading block 521150507 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes Force rewrite? yes Directory inode 130285580, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 130285580. Fix? yes Setting filetype for entry '.' in ??? (130285580) to 2. Missing '..' in directory inode 130285580. Fix? yes Setting filetype for entry '..' in ??? (130285580) to 2. Error reading block 521150792 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes Force rewrite? yes Directory inode 130286312, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 130286312. Fix? yes Setting filetype for entry '.' in ??? (130286312) to 2. Missing '..' in directory inode 130286312. Fix? yes Setting filetype for entry '..' in ??? (130286312) to 2. Error reading block 521150836 (Attempt to read block from filesystem resulted in short read) while reading directory block. Ignore error? yes [144/276] Force rewrite? yes Directory inode 130286356, block #0, offset 0: directory corrupted Salvage? yes Missing '.' in directory inode 130286356. Fix? yes Setting filetype for entry '.' in ??? (130286356) to 2. Missing '..' in directory inode 130286356. Fix? yes Setting filetype for entry '..' in ??? (130286356) to 2. Entry 'dbSubExample.c.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/l wo/W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/unu sed inode 131859914. Clear? yes Entry 'Makefile.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo/W1/ SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/unused in ode 131859913. Clear? yes Entry 'dbSubExample.dbd.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps /lwo/W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/u nused inode 131859915. Clear? yes Entry 'devXxxSoft.c.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo /W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/unuse d inode 131859916. Clear? yes Entry 'epicsHLTSHello.c.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps /lwo/W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/u nused inode 131859917. Clear? yes Entry 'epicsHLTSHello.dbd.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldap ps/lwo/W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted /unused inode 131859918. Clear? yes Entry 'epicsHLTSMain.cpp.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapp s/lwo/W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/ unused inode 131859919. Clear? yes Entry 'initTrace.c.svn-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo/ W1/SUS/HLTS/epics/epicsHLTSApp/src/.svn/text-base (131859215) has deleted/unused inode 131859920. Clear? yes Entry 'libepicsHLTSSupport.dylib' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps [97/276] /lwo/W1/SUS/HLTS/epics/lib/darwin-x86 (131859899) has deleted/unused inode 13185 9907. Clear? yes Entry '.svn' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo/W1/SUS/HLTS/epic s/lib/darwin-x86 (131859899) has deleted/unused inode 131859908. Clear? yes Entry 'props' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo/W1/SUS/HLTS/epi cs/lib/.svn/tmp (131859903) has deleted/unused inode 131859905. Clear? yes Entry 'text-base' in /rtcds/userapps/tags/H2OAT_RCG2.5.1/oldapps/lwo/W1/SUS/HLTS /epics/lib/.svn/tmp (131859903) has deleted/unused inode 131859906. Clear? yes Entry '..' in ??? (131989505) has deleted/unused inode 131859912. Clear? yes Entry '..' in ??? (131989506) has deleted/unused inode 131859912. Clear? yes Entry '..' in ??? (131989507) has deleted/unused inode 131859912. Clear? yes Pass 3: Checking directory connectivity '..' in /rtcds/userapps/trunk/sus/x1/medm/.svn/tmp/prop-base (129893610) is (0), should be /rtcds/userapps/trunk/sus/x1/medm/.svn/tmp (12976262 3). Fix? yes '..' in /rtcds/userapps/branches/branch-2.4/isi/m1/medm/.svn/tmp/prop-base (1302 85571) is (0), should be /rtcds/userapps/branches/branch-2.4/is i/m1/medm/.svn/tmp (130285570). Fix? yes '..' in /rtcds/userapps/branches/branch-2.4/isi/m1/medm/.svn/tmp/props (13028557 2) is (0), should be /rtcds/userapps/branches/branch-2.4/isi/m1 /medm/.svn/tmp (130285570). Fix? yes '..' in /rtcds/userapps/branches/branch-2.4/isi/m1/medm/m1isihamx/.svn/tmp/props (130285580) is (0), should be /rtcds/userapps/branches/branch- 2.4/isi/m1/medm/m1isihamx/.svn/tmp (130285578). Fix? yes '..' in /rtcds/userapps/branches/branch-2.4/oldapps/ISI/common/.svn/tmp/props (1 30286312) is (0), should be /rtcds/userapps/branches/branch-2.4 /oldapps/ISI/common/.svn/tmp (130286310). Fix? yes '..' in /rtcds/userapps/branches/branch-2.4/oldapps/ISI/common/src/.svn/props (1 30286356) is (0), should be /rtcds/userapps/branches/branch-2.4 /oldapps/ISI/common/src/.svn (130286354). [50/276] Fix? yes Unconnected directory inode 131989505 (...) Connect to /lost+found? yes /lost+found not found. Create? yes Unconnected directory inode 131989506 (...) Connect to /lost+found? yes Unconnected directory inode 131989507 (...) Connect to /lost+found? yes Pass 4: Checking reference counts Inode 2 ref count is 18, should be 24. Fix? yes Inode 129762623 ref count is 6, should be 5. Fix? yes Inode 130285570 ref count is 7, should be 5. Fix? yes Inode 130285578 ref count is 6, should be 5. Fix? yes Inode 130286310 ref count is 6, should be 5. Fix? yes Inode 130286354 ref count is 7, should be 6. Fix? yes Inode 131859899 ref count is 3, should be 2. Fix? yes Inode 131859903 ref count is 5, should be 3. Fix? yes Unattached inode 131859971 Connect to /lost+found? yes Inode 131859971 ref count is 2, should be 1. Fix? yes Unattached inode 131859972 Connect to /lost+found? yes Inode 131859972 ref count is 2, should be 1. Fix? yes Unattached inode 131859973 Connect to /lost+found? yes Inode 131859973 ref count is 2, should be 1. Fix? yes Unattached inode 131859974 Connect to /lost+found? yes [3/276] Inode 131859974 ref count is 2, should be 1. Fix? yes Unattached inode 131859975 Connect to /lost+found? yes Inode 131859975 ref count is 2, should be 1. Fix? yes Unattached inode 131859976 Connect to /lost+found? yes Inode 131859976 ref count is 2, should be 1. Fix? yes Inode 131989505 ref count is 3, should be 2. Fix? yes Inode 131989506 ref count is 3, should be 2. Fix? yes Inode 131989507 ref count is 3, should be 2. Fix? yes Pass 5: Checking group summary information Block bitmap differences: -(527442555--527442561) -(527485932--527485939) Fix? yes Free blocks count wrong for group #16096 (368, counted=375). Fix? yes Free blocks count wrong for group #16097 (11717, counted=11725). Fix? yes Free blocks count wrong (86455130, counted=86455145). Fix? yes Inode bitmap differences: -(131859905--131859920) Fix? yes Free inodes count wrong for group #16096 (6468, counted=6484). Fix? yes Directories count wrong for group #16096 (617, counted=610). Fix? yes Free inodes count wrong (128011591, counted=128011607). Fix? yes /dev/sde1: ***** FILE SYSTEM WAS MODIFIED ***** /dev/sde1: ***** FILE SYSTEM WAS MODIFIED ***** /dev/sde1: 6206121/134217728 files (1.8% non-contiguous), 450415510/536870655 bl ocks controls@chiara|~> sudo mount -a [sudo] password for controls: mount: special device UUID="90a5c98a-22fb-4685-9c17-77ed07a5e000" does not exist controls@chiara|~> controls@chiara|~> sudo fsck -yV UUID="90a5c98a-22fb-4685-9c17-77ed07a5e000" fsck: couldn't find matching filesystem: UUID=90a5c98a-22fb-4685-9c17-77ed07a5e000