Message ID: 1721     Entry time: Wed Jul 8 11:08:43 2009
Author: Zach 
Type: Update 
Category: Cameras 
Subject: GigE Phase Camera 

The plan for the optical setup has been corrected after it was realized that it would be impossible to isolate a 29.501 MHz frequency from a 29.499 MHz one because they are so close in value.  Instead, we decided to adopt the setup pictured below.  In this way, the low-pass filter should have no trouble isolating 29.501-29.5 MHz from 29.501 + 29.5 MHz.  Also, we decided to scrap the idea of sending Alberto's laser through a fiber optic cable after hearing rumors of extra lasers.  Since I shouldn't have to share a beam when the second laser comes in, I plan on setting up both lasers on the same optics bench.  I've been working on the software while waiting for supplies, but I should be able to start building the trigger box today (assuming the four-pair cable is delivered).

Attachment 1: fig1.pdf  19 kB  | Hide | Hide all
fig1.pdf
Attachment 2: fig2.pdf  19 kB  | Hide | Hide all
fig2.pdf